Skip to content

M110P Microfluidizer® Processor

A 'Plug & Play' High Shear Benchtop Processor

The Microfluidizer® M110P processor is a premium lab-scale model that is ready to set to work. It's a simple-to-use, electric benchtop fluid homogenizer.

Using the Microfluidics fixed-geometry Interaction Chamber™ technology and a ceramic (Zirconia) plunger, the M110P is capable of successfully processing a wide variety of fluids, including oil-in-water emulsions, solids-in-liquid suspensions and performing cell disruption of yeasts and plant cells — much of which is performed with as few as one or two passes.

The M110P is powered by a standard 20-amp single-phase electrical outlet. The onboard 1.5 kW (2 HP) electric-hydraulic drive powers a single-acting intensifier pump. Process pressures are adjustable up to 2068 bar (30,000 psi) to produce the desired product results. No need for compressed air or hydraulic cooling water.

This versatile laboratory homogenizer conveniently fits under most standard laboratory chemical hoods.

The lab scale M110P delivers a repeatable process with results that are guaranteed to scale up to pilot and production volumes.

Download the Brochure

M110P-transparent

View the Gallery


M110P Microfluidizer® Processor

Features

Standard Features

  • 300 ml Glass Feed Reservoir
  • Diamond Interaction Chamber™
  • Ceramic (Zirconia) plunger
  • Stainless steel enclosure
  • Electric/hydraulic drive method
  • Mechanical product pressure gauge

 

Optional Features

  • Larger capacity glass or stainless-steel reservoirs
  • Temperature sensors displayed on HMI
  • Sanitary flush diaphragm pressure transducer displayed on HMI
  • Batch processing 
  • Seal quench system

Biopharma Features

  • Includes all features required to achieve cGMP as specified by the American Society for Mechanical Engineers Bioprocessing Equipment (ASME BPE)
  • Traceability – Material Certificates for all product contact parts included in an electronic Turnover Package (TOP)
  • Surface Finish – Electropolished and passivated to achieve surface finish of < 20 Ra where possible.
  • USP Class VI elastomers
  • Drainability – A sanitary heat exchanger, a sanitary flush pressure transducer and pitched piping are included to ensure all equipment can be drained effectively.
Download the Biopharma Brochure

Optional Biopharma Features

  • Larger stainless steel reservoirs
  • Batch processing  
  • Seal quench system
  • Preventative maintenance service
  • IQ/OQ documentation and execution
cgmp-compliant-icon

The M110P benchtop processor model is recommended for a variety of applications.

Because the M110P offers flexibility in the volumes that can be processed and delivers repeatable, scalable results, it is ideally placed to be used to create:

It is so easy to use and set up which makes it an ideal machine for the lab, as it will be shared by multiple users. In addition, it is easy to clean and requires very little maintenance.

CellDisruption-mehod-blog (1)
M110P Microfluidizer® Processor

Specifications

The Standard and Biopharma M110P Benchtop Processor Specifications Include:

  • Operating pressure of up to 30,000 psi/2068 bar
  • Minimum sample size - 50 ml
  • Flow rate - up to 120 mL/min
  • Power - 60 hz / 230 V 
  • Noise - 80 dB TWA
HOMOGENIZATION EQUIPMENT DESIGNED FOR SCALABLE PROCESSING

Our Range of High-Pressure Lab,
Pilot and Production Processors

Featured Resources

Related Guides and Information

resource

Microfluidics Celebrates 40 years of Solving Nanotechnology Challenges

Nov 1, 2023 7:53:22 PM

Microfluidics is celebrating its 40th year and this blog explores & celebrates..

resource

Microfluidics presents at the ECCPM FORUM 2023

Oct 2, 2023 9:00:00 AM

Microfluidics International Corporation was proud to have Steve Mesite,..

resource

RNA Therapeutics & Delivery U.S 2023

Jun 29, 2023 4:04:21 PM

Dr. Yang Su, Manager of New Technology and Applications at Microfluidics..

M110P Microfluidizer® Processor

FAQs

Microfluidizer® technology is differentiated from other technologies because results are repeatable batch-to-batch and because results from lab environments can seamlessly be scaled to pilot and production volumes.

The M110P is an ideal benchtop processor for scaleup. Many of our customers have scale up to pilot scale with the M815 and the M110EH. Other customers have seamlessly scaled to our production models.

 Microfluidics combines expert application knowledge with proven and consistent equipment technology to help our customers reach their nanotechnology goals.

Microfluidics offers a full range of Microfluidizer® processors designed specifically for pharmaceutical and biotech applications. Our equipment includes benchtop, pilot and production scale models to meet our customers volume requirements. These processors are engineered with cGMP compliance in mind. Learn more about our Biopharma equipment: https://www.microfluidics-mpt.com/biopharmaceutical-manufacturing-equipment

 Our Microfluidics team is made up of application engineers and subject matter experts. With a deep understanding of nanotechnology challenges our team will ask a full range of questions to best understand each customer's problem and ensure goals are aligned. Our team provides a detailed report of all test results and can be trusted to adhere to a strict confidentiality agreement. Our team offer three different reports: proof of concept, process optimization and scaleup testing. Learn more.